High-Voltage Dynamic Static Var Compensator (MSVC)

Rsafele offers High-Voltage Dynamic Static Var Compensator (MSVC).

Discover

High-Voltage Dynamic Static Var Compensator (MSVC)

High-Voltage Dynamic Static Var Compensator (MSVC) is a high-voltage reactive power compensation solution designed for 6kV–110kV AC power grids. It regulates the inductive reactive power output of the magnetically controlled reactor to balance the capacitive reactive power supplied by the capacitor compensation (or filter) branch, enabling continuous and flexible output of both inductive and capacitive reactive power. Connected in parallel with the power grid, the system is widely used in substations, power plants, industrial power distribution systems, and other applications with fluctuating reactive power demand. It improves power factor, stabilizes grid voltage, reduces voltage fluctuations and transmission losses, and increases power utilization efficiency. The capacitor branch can also be configured as a harmonic filter to suppress specific harmonic frequencies while providing reactive power compensation. Its flexible reactive power regulation makes it suitable for improving power quality and maintaining stable operation in medium- and high-voltage power systems.

High-Voltage Dynamic Static Var Compensator (MSVC)

Benefits

  • Continuous Smooth Regulation
  • Fast Dynamic Response
  • Combined Harmonic Filtering and Compensation
  • No Switching Oscillations

Features

High-Voltage Dynamic Static Var Compensator (MSVC)
  • Rated Voltage & Capacity: Available for 6kV, 10kV, 20kV, 35kV and 66kV systems. Maximum MCR branch capacity: 50,000 kvar; maximum FC branch capacity: 100,000 kvar. MCR unit capacities follow the GB/T 321 R10 preferred number series for flexible configuration.
  • Continuous Regulation Range: MCR output is continuously adjustable from 5% to 100% of rated capacity, without interruption or step changes caused by capacitor bank switching.
  • Overload Capability: Supports continuous operation at up to 110% of rated capacity.
  • Dynamic Response Time: 80–300 ms, reaching 90% of the target output without overshoot after a step control signal.
  • Load Adaptability: Quickly tracks fluctuating reactive power demands from electric arc furnaces, rolling mills and hoisting equipment, helping suppress voltage flicker and voltage dips.
  • [pic]
US English ▼